◇ Full automatic loading and unloading design, connecting to other machines is available
◇ head OD detection
◇ Stem diameter
◇ Groove diameter
◇ Gauge line-top face
◇ Gauge line-tip end
◇ Gauge line-groove
◇ head run-out
◇ Stem straightness((probe accuracy 0.00005)
◇ groove – tip end
◇ Face- run-out
◇ End face run-out
◇ Stem end run out
◇ Laser marking
◇ Automatic removal NG products
◇ Failure self-diagnosis system
Range of Application | |||
Valve stem diameter | Φ4.5mm-φ10mm | Valve face diameter | Φ20mm-φ50mm |
Valve head length | 80mm-200mm | ||
Main data | |||
OEE | ≥90% | Change type time | ≤60min |
GR&R | ≤10% | Inspection C/T | ≤5S/PCS |